TM 9-2350-222-20-1-4
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR (Sheet 3 of 22)
Battery Generator Indicator Replacement (Sheet 1 of 2)
TOOLS: 3/8 in. combination box and open end wrench
SUPPLIES: Silicone compound (Item 32, Appendix D)
Lockwasher (MS35338-43) (2 required)
PRELIMINARY PROCEDURE:
REMOVAL:
1.
Remove lead (circuit 27) from rear of indicator (A) by pulling out.
2.
Using wrench, remove two nuts (B) and
mounting bracket (D) to panel. Throw
3.
Remove indicator (A) and mounting bracket (D).
INSTALLATION:
1.
Apply silicone compound (Item 32, Appendix D) to indicator (A) electrical connector.
Go on to Sheet 2
TA139686