TM 9-2350-222-20-1-4
GENERATOR REPLACEMENT (Sheet 3 of 15)
NOTE
During the remainder of the removal procedure, the screws
and clamps are all one piece. The screws are turned until the
clamp comes apart.
Using screwdriver, turn two screws (G) removing clamps (H) securing flexible boot (J) to generator
7.
(F).
8.
Using screwdriver, turn screw (K) removing clamp (L) from flexible boot (J)
Disconnect flexible boot (J) from exhaust tube (M).
9.
Using 1-1/8 inch wrench, remove electrical connector (N) from generator connector (P).
10.
Go on to Sheet 4
TA139561
10-6