TM 9-2350-222-20-1-3
MANIFOLD HEATER FUEL RETURN TUBE ASSEMBLY REPLACEMENT (Sheet 3 of 3)
INSTALLATION:
Install tube assembly (A) through opening in shroud.
1.
2.
Connect tube assembly (A) to elbow (B).
3.
Connect tube assembly (A) to elbow (C).
4.
Position new `grommet (D) onto tube assembly (A) and to shroud.
5.
Using wrench, tighten tube assembly (A) coupling nuts at elbows (B) and (C).
6.
Operate primer pump (TM 9-2350-222-10). Check for leaks. Make necessary repairs.
7.
End of Task
TA148938
7-390