FUEL-WATER SEPARATOR OPERATIONAL TESTS (2D ENGINE) (Sheet 10 of 11)
11. Remove tip of lower (G) sensor probe from water in metal container (H) before 15 seconds have gone by
from time of putting it in and check if fluid stops draining from solenoid drain tube (K).
12.
If fluid does not start draining (step 9), does
not keep draining (step 10), or does not stop
draining (step 11), refer to troubleshooting
procedures (see page 4-1).
Disconnect cable (F-7, Appendix F) from both
13.
terminals of power source (L).
14,
Disconnect connector (M) at fuel-water separa-
tor control box (N).
15.
Disconnect cable (P) (Figure F-8, Appendix F)
from power source (L).
16.
Disconnect cable (P) (Figure F-8, Appendix F)
from metal container (H).
17.
Remove metal container (Q) from under sole-
noid drain tube (K).
18.
Using pliers, connect engine electrical harness
connector (R) to fuel-water separator control
box (N) by turning clockwise.
Go on to Sheet 11