FUEL-WATER SEPARATOR OPERATIONAL TESTS (2D ENGINE) (Sheet 7 of 11)
WARNING
To avoid shock and Inaccurate test results:
Do not let upper (E) and lower (F) sensor probes come into
direct contact with each other.
Do not let upper (E) or lower (F) sensor probes come into
contact with metal container (G).
Hold insulated cables (H) attached to upper (E) and lower (F)
sensor probes. Do not touch either probe.
Hold tips of upper(E) and lower(F) sensor
8.
probes in water in metal container (G) until
fluid stops draining from solenoid drain
--
tube (J).
If fluid does not stop draining from solenoid
9.
drain tube (J) within 15-20 secOndS from
starting, refer to troubleshooting procedures
(see page 4-337).
If fluid does begin draining, go to sequential
10.
drain test on next page.
Remove upper (E) and lower (F)
11.
sensor probes from metal container (G).
Go on to Sheet 8
TA253234