TM 9-2350-222-20- 1-3
AIR CLEANER DOOR REPLACEMENT (TOP LOADING) (Sheet 1 of 3)
9/16 in. combination box and open end wrench
TOOLS:
Hammer (or mallet)
Long round nose pliers
Slip joint pliers
Low pressure compressed air facility
Gasket
SUPPLIES:
Cotter pins (3 required)
Goggles (Item 74, Appendix D)
Leather gloves (Item 72, Appendix D)
Loctite adhesive (Item 75, Appendix D)
Face shield (Item 76, Appendix D)
REMOVAL:
WARNING
To prevent screws from pulling out of
box and injuring personnel, a minimum of
200 pounds must be placed atop the
door before attempting to remove
screws.
NOTE
If captive screws are used, they will only
be loosened and not removed.
1.
Using wrench, remove three screws (A).
2.
Using pliers, pull three cotter pins (B) out
o f three straight pins (C). how cotter pins
away.
Remove flat washers (D).
3.
4.
Using hammer, tap straight pins (C) free of
door hinges (E).
5.
Using pliers, pull three straight pins (C) from
door hinges.
6.
Lift door assembly (F) and remove it from
air cleaner housing (G).
Go on to Sheet 2
7-103
Change 4