TM 5-5420-226-20-1
Symptom-74
DETAILED
TROUBLESHOOTING
PROCEDURE
SUPPORT
SYSTEM
- PERSONNEL
HEATER
(Continued)
o
STEP
9
CONTINUED
n
IFirstTechnician(CommandersStation)
I
l Check if meter indicates
continuity.
(
[
Does met er indicate
continuity?
I
)
l Inspect
basket-control
panel
heater
harness
for bent/bro-
ken
connector
contacts
or
loose CKT 401 wire at rear of
connectors.
l Repair connectors
if defective
(page
10-298).
l if
connectors
are
not
defective,
notify
support
maintenance
of
a
defective
basket-control
panel
heater
harness.
l Connect
basket-control
panel
heater
harness
connector
to
master
control
panel.
l Instaii
master
control
panel
(page
10-33).
l Install
basket-control
panel
heater
harness
at
basket
disconnect.
,
TA107399
4-710