TM 5-5420-226-20-1
DETAILED
TROUBLESHOOTING
PROCEDURE
INDICATOR
- GAGE
Symptom-35
(Continued)
.
TRANSMISSION
OIL
TEMPERATURE
GAGE
SHOWS
HIGH
OR NO
TEMPERATURE
(POWERPLANT
WARNING
LAMP
NOT
ON ENGINE
RUNNING
ALL
OTHER
GAGES
READ
NORMAL),
~
NOTE
This procedure
is to be performed
by
two
persons.
The
lead
person
is
referred
to as the first technician
and
shall direct the activity of the second
person called the second technician.
s
(Check
gage instrument
panel harness
(CKT 27) at
TRANSMISSION
TEMP indicator
gage for electrical
power.
First
l
l
l
l
l
l
l
Technician
(Operators
Station)
Set MASTER
BATTERY
switch
OFF.
Displace
gage instrument
panel
(page
10-111).
Disconnect
gage instrument
panel
harness
connector
(CKT
27) from
TRANSMISSION
TEMP
indicator
gage.
Set multimeter
to measure
18 to 30 volts dc, or use STE/
ICE Test No. 89 (page 4-81).
Connect red probe of meter to gage instrument
panel
harness
connector
(CKT
27) and black probe to ground.
Set MASTER
BATTERY
switch
ON,
Check
if meter
indicates
18 to 30 volts
dc.
Does meter
indicate
18 to 30 volts dc?
I
+---
TO VEHICLE
GROUND
ITRANSMISSION
TEMP
INDICATOR
,\
GAGE
\
\
GAGE
INSTRUMENT
PANEL
L
(REAR
VIEW)
(page 10-298).
D-s
TA10714
.
4-455