TM 5-5420-226-20-1
Symptom-31
FROM
STEP
o
9
I
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- HULL POWER
(Continued)
z
Check front accessory harness (CKT 1) from
connector at voltage regulator to connector at
bulkhead disconnect for continuity.
Second Technician (Left Top Deck Grille Doors)
l
First
l
l
l
Connect bulkhead engine disconnect harness connector
to engine disconnect.
Technician
(Commanders
Station)
Displace front accessory harness connector (CKT 1) at
bulkhead disconnect
(page 10-269).
Connect red probe of meter to contact C (CKT
1) of
front accessory harness connector
at bulkhead
disconnect.
Connect black probe of meter to contact D (CKT 1) of
front accessory harness connector at voltage regulator.
.
CO~TACT
C
(CKT 1)
TA107O95
4-406