TM
5-5420-226-20-1
Symptom-5
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STARTING
T
(Continued)
Check
circuit
76 for continuity
from connector
contact
to capacitor
lead connector.
Second
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
OFF.
First
Technician
(Engine
Compartment)
l Remove capacitor
connector
and housing
assembly
from cable and adapter
assembly
(page
10-326).
l Set multi meter to OHMS Xl scale and zero meter, or
use STE/ICE
Test
No. 91 (page
4-83).
l Connect red probe of meter to capacitor
lead connector.
l Connect black probe of meter to capacitor
and housing
assembly
connector
(CKT
76).
l Check if meter indicates
continuity.
Does meter
indicate
continuity?
n
~m~
o-+0
=%
l
CKT 76
l .
d
.
fl-
. .
%
-.
..
23
A// -
,.
CAPACITOR
LEAD
-a<
)
Repair capacitor
and housing
assembly
(page
10-326).
TA106867
4-178